Opened 12 years ago

Closed 11 years ago

#418 closed Bug Report (wontfix)

Controls don't show correct minimum and maximum value.

Reported by: Ulrich Lorenz Schlüter <audio-mobster@…> Owned by: David Robillard
Priority: minor Component: FlowCanvas
Keywords: Cc:

Description

This:

a lv2:ControlPort, lv2:InputPort;
lv2:index 3;
lv2:symbol "bpm";
lv2:name "BPM";
lv2:minimum 1;
lv2:maximum 500;
lv2:default 135;

ends up in a control with a minimum of 0 and a maximum of 135.

Change History (1)

comment:1 Changed 11 years ago by David Robillard

Resolution: wontfix
Status: newclosed

This data is incorrect. "1" is an integer, not a floating point number. LV2 range values should be floating point numbers.

I could, and perhaps should, make SLV2 deal with this situation, but it's unlikely every implementation would, so the data should be fixed anyway.

Note: See TracTickets for help on using tickets.